product catalogue: eft
Bursts or EFTs (electrical fast transients) are caused by operation of electro-mechanical switches, motors and distribution switch-gear connected to the power distribution network. A typical burst consists of a large number of recurring impulses at high frequency for a short time period. To cover EFT/Burst test requirements from 100V to 8kV, we offer two basic stand-alone products, PEFT 4010 and PEFT 8010. EFT/Burst tests up to 4.2kV can also be carried out with the Haefely EMC compact test station ECOMPACT 4. All our EFT/Burst generators are 100% compliant to the latest standards, including the IEC/EN 61000-4-4 edition 2, which is mandatory from October 2007.
PEFT 4010 The PEFT 4010 is a complete stand-alone EFT/Burst generator designed to meet the requirements of IEC/EN 61000-4-4 edition 1 & 2. It covers a voltage range from 100V to 4.8kV, and has an integrated 16A single phase CDN. Depending on your test requirements, we offer a number of options and accessories to fully cover your needs, these include three phase 32A and 100A CDNs, capacitive coupling clamps, verification equipment, and various other valuable accessories necessary for a complete EFT test setup.  | Features - impulse voltage up to 4'800V
- spike frequency 1Hz to 2MHz
- 5 burst modes
- 12'000 impulses per second
- integrated 16Aac/10Adc CDN
- internal or external burst synchronisation
- parameter modification while a test is running
- 18 program and 18 test memory locations with battery backup
- control of PESD 1610 ESD generator
- Centronix printer interface
- hand held remote control unit
|
One solution for: IEC/EN 61000-4-4 edition 1 & 2, ETSI 300 386-2, Bellcore-1089/section 9.10.5 Benefits Consistent pulse parameters
Totally reproducible test results | Fully automated by WinFEAT&R control |
PEFT 8010 The PEFT 8010 is a complete stand-alone EFT/Burst generator designed to meet the requirements of IEC/EN 61000-4-4 edition 1 & 2. It covers a voltage range from 1000V to 7.3kV, and has an integrated 16A single phase CDN. Depending on your test requirements, we offer a number of options and accessories to fully cover your needs, these include three phase 32A and 100A CDNs, capacitive coupling clamps, verification equipment, and various other valuable accessories necessary for a complete EFT test setup.  | Features - impulse voltage up to 7.300V
- spike frequency 100kHz
- 225 impulses per second
- integrated 16Aac/10Adc CDN
- internal or external burst synchronisation
- parameter modification while a test is running
- 18 program and 18 test memory locations with battery backup
- control of PESD 1610 ESD generator
- Centronix printer interface
- hand held remote control unit
|
One solution for: IEC/EN 61000-4-4 edition 1 & 2, ETSI 300 386-2, Bellcore-1089/section 9.10.5 Benefits Consistent pulse parameters
Totally reproducible test results | Fully automated by WinFEAT&R control |
accessoriesIP4A - Capacitive Coupling Clamp The IP4A is a capacitive coupling clamp for superposition of bursts on data lines in accordance with IEC/EN 61000-4-4.- maximum cable size 40mm
- minimum test cable length 1m
- maximum EFT voltage 8kV
- coupling plane mounted on 0.1m insulation block
- handy carrying handle
|  | | |
| FP-EFT 32M - Manual 3ph CDN, 32A The FP-EFT32M is a manual three phase Coupling / Decoupling Network for operation up to 32A, controlled directly from the PEFT4010 or PEFT8010 front panel- 690Vac phase-phase, 400Vac phase-neutral
- 32A per phase EUT current
- maximum EFT voltage 8kV
- IEC/EN 61000-4-4 edition 1&2
- ANSI C62.41 & C37.90.1
|   | | |
| FP-EFT 100M - Manual 3ph CDN, 100A The FPEFT100M is a manual three phase Coupling / Decoupling Network for operation up to 100A for AC & DC- test object power line voltage max.690Vac
- test object power line voltage max.110Vdc
- test object current max. 100A per phase
- manual coupling path selection
- meets IEC and ANSI coupling requirements
- maximum EFT voltage 8kV
- integrated network to protect EFT generator
|   | | |
| EFT Verification Attenuator Set According to the latest changes in the IEC/EN 61000-4-4 edition 2 standard, which is mandatory since October 2007, verification of the burst waveform is required through a 50 and 1000 ohm load. The Haefely EMC EFT Verification set includes all neccessary attenuators and additional cabling and documentation, that allow users to connect to comercial oscilloscopes and verify the waveshape as required by the latest standard. To verify impulses at the CDN output, special adapters can be used together with the attenuators. . |   | | | WinFEAT&R Software The WinFEAT&R software is the latest generation of control and reporting software, based on a modern Drag and Drop concept, which offers such simplicity of use, that even users with minimum technical experience, will by carrying out tests in no time. This unique software allows users to run user specified or pre-defined tests according to the latest standards, and monitors and displays real time output current and voltage values. The software runs under all latest Microsoft Windows versions and is compatible with all stand alone Haefely EMC test generators. |   | | | IEEE 488 interface GPIB interface board for the PEFT4010 mainframe |  | | |
| Fiber optic interface Fiber optic interface / RS232 converter used to connect the ESD generator PESD1610 with PEFT4010 mainframePESD 1610 - ESD generator For more information see in the ESD (electrostatic discharge testers) product line. |  | | |
| | | | |
| Real Burst Additional circuit boards can be fitted to the PEFT 4010, enabling it to produce burst packets as they occur in reality, that is with simultaneously varying frequency and amplitudes. Two frequency options can be added, 5KHz and 100KHz. |  | | |
| Remote Control Unit When PEFT 4010 is operated on a floor mounted Ground Reference Plane, access to the instrument front panel may not be so convenient. The Easy Control, enables use of the PEFT 4010 when the instrument front panel is not visible or inconveniently placed. |  | | |
| Field Probes - Near field injection probes E and H field generation probes set. Used for development and diagnostic to generate interference fields into your test object to find sensitive areas. (powered by PEFT4010 output) |  | | |
| Field Probes - Scan EM probes ("Sniffer") Set of two high sensitive probes for the detection of electric and magnetic fields. Used for product development and diagnostic. |  | | |
| External Warning Lamp Connected to any generator, the additional, stand-alone widely seen warning lamp indicates clearly the status of the test equipment by red & green lights.External Emergency Stop Switch Connected to any generator, the EMERGENCY STOP SWITCH, when activated instantly discharges high voltage circuits and switches off power to the EUT. |  | | |
| | |
Verification Adaptor To verify and measure the PEFT4010 output wave shape. Adaptor from SCHUKO connector to high voltage BNC connectors. Used together with the measurement attenuators. Optical DEC95 - Optical link for RS232 10m optical link cable for RS232 connection of the PEFT 4010 to an external PC. Complete electrical decoupling to prevent external disturbances or coupling into the PC.
|