| Standards | Purpose / Description | Model | Remarks |
| IEC/EN/IEEE |
IEC/EN 61000-4-2 Electrostatic Discharge
| Requirements for simulating Electrostatic Discharge | PESD 1610 PESD 3010 | 16.5kV air, 9kV contact 30kV air, 30kV contact |
IEC/EN 61000-4-4 Electrical Fast Transients
| Requirements for simulating EFT/Burst, on power and data and control lines | PEFT 4010 PEFT 8010 ECOMPACT 4 | Up to 4.8kV Up to 7.3kV Up to 4.2kV |
IEC/EN 61000-4-5 ANSI C62.41 1.2/50µs, 8/20µs Combination wave
| Requirements for simulating surges on power and I/O lines | ECOMPACT 4 PSURGE 4010 PLATFORM PSURGE 30.2 | Up to 4.2kV Up to 4.2kV Up to 7.4kV Up to 30kV |
IEC/EN 61000-4-5 Surge 10/700us Telecom wave
| Requirements for simulating surges on telecommunication lines | PLATFORM | Up to 8kV |
IEC/EN 61000-4-8 AC magnetic fields
| Requirements for magnetic fields generated by AC power mains | MAG 100 MFS 100 | Up to 100A/m Up to 100A/m |
IEC/EN 61000-4-9 Pulse magnetic fields
| Requirements for pulsed magnetic fields generated by power stations etc. | MSURGE MFS 100 | Up to 3000A/m Up to 1100A/m |
IEC/EN 61000-4-10 Oscillating magnetic field
| Requirements for testing oscillating magnetic field. | PLATFORM | 100kHz & 1MHz Field strenght 100A/m |
IEC/EN 61000-4-11 Dips, Interrupts
| Requirements for voltage fluctuations of the mains (dips, variations, interrupts) | PLINE 1610 ECOMPACT 4 | Selectable voltage output range 0V.. 264V |
IEC/EN 61000-4-12 Surge ring and oscillating wave
| Requirements for simulating 100kHz ring wave and 100kHz & 1MHz damped oscillating wave | PLATFORM | Up to 7.8kV |
IEC/EN 61000-4-18 Surge damped oscillating wave
| Requirements for simulating 100kHz and 1MHz damped oscillating wave | PLATFORM | Up to 3.3kV |
IEC/EN 60255-22-1 IEC/EN 60255-3 Surge ring and oscillating wave
| Requirements for simulating 100kHz ring wave and 1MHz damped oscillating wave | PLATFORM | Up to 7.7kV |
IEEE 1613 Substation equipment
| Requirements for simulating 100kHz ring wave and 1MHz damped oscillating wave | PLATFORM | 100kHz & 1MHz Up to 3.3kV |
IEEE C37.90.1 1MHz damped sine & EFT
| Surge withstand capability for relays and relay systems | PLATFORM PEFT 4010 | Up to 7.7kV Up to 4.8kV |
IEC/EN 60950 Lightning pulse & 10/700µs
| Requirements for testing safety of Information Technology Equipment | PLATFORM
| Up to 8kV partial |
IEC/EN 60950 1nF Surge testing on IT equipment
| Requirements for surge testing on IT equipment connected to outdoor antennas | PS 1500 | Up to 15 kV |
IEC/EN 61010 Surge combination wave
| Requirements for testing safety of electrical laboratory equipment | PSURGE 30.2 | Up to 30kV |
IEC/EN 61010 IEC/EN 60060 IEC/EN 60335 IEC/EN 61180
| Insulation testing requirements 1.2/50. | PLATFORM | Up to 15kV |
IEC/EN 60664 Surge combination wave
| Requirements for insulation coordination within low voltage systems | PSURGE 30.2 | Up to 30kV |
IEC/EN 60060-2 Lightning wave
| High voltage test techniques for general applications | PLATFORM PSURGE 30.2 | Up to 7.4kV Up to 30kV |
IEC/EN 60065 clause 10 & 14
| Tests on equipment and component insulation | PS 1500 PLATFORM | Up to 15kV |
IEC/EN 61000-6-1/ & 2 Dips, Interrupts
| Requirements for voltage fluctuations of the mains (dips, variations, interrupts) | PLINE 1610 | Selectable voltage output range 0V.. 264V |
IEC/EN 61000-6-1 & 2 ESD
| Requirements for simulating human ESD | PESD 1610 PESD 3010 | 16.5kV air, 9kV contact 30kV air, 30kV contact |
ENV 50141 ESD
| Requirements for simulating human ESD | PESD 1610 PESD 3010 | 16.5kV air, 9kV contact 30kV air, 30kV contact |
| Automotive ISO |
ISO TR10605 ESD
| Requirements for simulating human ESD | PESD 3010 | 30kV air, 30kV contact |
| MIL |
MIL1541, 331A, STANAG 4239, ISO 7637, JEC, ... ESD
| Requirements for simulating human ESD | PESD 3010 | 30kV air, 30kV contact with additional impulse modules |
| ANSI |
ANSI C62.41 ANSI C62.45 Surge ring wave, Combination wave
| Surge voltages in AC power systems. EFT/Burst requirements. | PLATFORM
PEFT4010 PEFT 8010
| Up to 7.7kV
Up to 4.8kV Up to 7.3kV |
ANSI C37.90.1 Oscillating wave
| Requirements for simulating switching interferences in AC power systems. EFT/Burst requirements.
| PLATFORM
PEFT 4010 PEFT 8010
| Up to 3.3kV
Up to 4.8kV Up to 7.3kV |
ANSI C62.31 Current pulse
| Requirements for testing Gas Discharge Tubes | PSURGE30.2 | Up to 30kA |
ANSI C62.31 ANSI C62.33 ANSI C62. 35 Current impulse testing
| Requirements for component testing with current impulses. | PLATFORM | 8/20 & 10/1000 current Ranging from 1A to 12kA. |
| ITU |
ITU K20 ITU K21 ITU K44 ITU K45 Surge combination waves & 10/700µs
| Requirements for simulating surges on telecommunication lines (on telecom repeaters, central office equipment) | PLATFORM PSURGE30.2 | Up to 8kV Up to 30kV |
ITU K20 ITU K44 ITU K45 Current impulse testing
| Requirements for current impulse testing. | PLATFORM | 8/20 & 10/1000 current Ranging from 1A to 12kA. |
ITU K22 Lightning pulse & ESD
| Overvoltage Resistibility testing of equipment connected to the ISDN T/S bus | PLATFORM PESD 1610 | Up to 8kV 16.5kV air, 9kV contact |
| ETSI |
ETSI/EN 300 386-2 Surge combination waves & 10/700µs
| Requirements for simulating surges on telecommunication lines (on telecom repeaters, central office equipment) | PLATFORM | Up to 8kV |
ETSI/EN 300 386-2 Electrical Fast Transients
| Requirements for simulating showering arc, on power and I/O lines | PEFT 4010 | Up to 4.8kV
|
| UL |
UL 943 Current impulse testing
| Requirements for current impulse testing. | PLATFORM | Requirements for current impulse testing. |
UL 1414 Section 16
| Discharge tests for line-by-pass and antenna coupling elements. | PS 1500 | Up to 15kV |
UL 1449 Table 34.1, 35.1 Combination waves
| Requirements for qualification tests for power line protectors (TVSS). | PLATFORM
| Up to 7.4kV
|
UL 1950 Lightning pulse & 10/700µs
| Requirements for testing safety of Information Technology Equipment | PLATFORM | Up to 8kV partial
|
| TIA (FCC) |
TIA-968-A (FCC part 68) Surge | Requirements for qualifying all telecom line connected equipment. (surges on telecom and power lines) | PLATFORM | Up to 8kV All waveforms |
| Telcordia (Bellcore) |
Telcordia GR-1089-CORE Section 4 (Bellcore)
| Requirements for simulating surges on central office telecom equipment. (on telecom and power lines | PLATFORM | Up to 8kV Section 4, 1st and 2nd Level Lightning Surge: 2, 4 & 24 wire |
Telcordia GR-1089-CORE Section 9.10.5 (Bellcore)
| Requirements for simulating showering arc, on power and I/O lines | PEFT 4010 | Up to 4.8kV
|
Telcordia GR-1089-CORE Section 2 (Bellcore)
| Requirements for simulating human ESD | PESD 1610 PESD 3010 | 16kV air, 9kV contact 30kV air, 30kV contact |