product catalogue: surge < 8kV
For Surge testing up to 8kV, the Haefely EMC surge system family offers a number of stand alone, modular, and compact tester products which have been specially designed according to type of surge test. Choice of product depends largely on the type of business and future plans of each individual customer. Stand alone surge products are designed in such a way that they fully cover and exceed the norm requirements, making stand alone surge testers ideal for Test Houses and R&D purposes. Modular systems can be continuously expanded by adding impulse modules to cover a vast number of surge standards and applications, and are also ideal for Test Houses and R&D purposes. Compact testers are designed for testing not only surge, but also cover other EMC phenomena such as EFT/Burst and Dips & Interrupts, making such tester types ideal for pre compliance and CE marking purposes. If you want to discuss your future business plans and are seeking advise on what type of equipment is ideal for your testing purposes, please contact our team of experts who will help you make the right choice. To view our surge solutions up to 8kV, please scroll down or go straight to the product by using the following links: PSURGE 4010 - Stand alone 4kV Combination wave TesterThe PSURGE4010 is a stand alone combination wave surge tester particularly designed to cover the requirements of IEC standards up to 4kV.  | Features - impulse voltage: 200V .. 4.2kV
- impulse current: 100A .. 2.1kA
- maximum impulse repetition rate 12 per minute
- positive, negative and user definable alt. polarity
- integrated CDN for 16A at 264Vac and 110Vdc
- impulse voltage, current and EUT current measurement
- test parameter ramp functions
- phase angle synchronization
- 18 test and 18 program memory locations
|
One solution for: IEC/EN 61000-4-5 Edition 1 & 2, EN 61000-6-1, EN 61000-6-2 Benefits Consistent pulse parameters
Totally reproducible test results | Cost effective solution
Fully automated by WinFEAT software |
ECOMPACT 4 - Compact 4kV testerThe ECOMPACT4 is a compact 4kV tester for performing combination wave surge tests plus EFT/Burst and Dips and Interrupts. To find out more about the compact tester, please follow the link.
PSURGE 8000 Platform - Modular 8kV surge systemThe PSURGE 8000 platform system is based on a modular concept, which gives users the capability of adding an unlimited number of modules to cover various surge tests up to 8kV, such as combination wave, ring wave, damped oscillatory wave, and many more. This modular system is used worldwide for covering several international stanards such as IEC, EN, ITU, FCC, ANSI, and many more. Below you will find more information on the available PSURGE 8000 platform system for power line testing, telecommunications testing, component testing and the available modules and CDNs. To find out more about the PSURGE 8000 platform system concept, please follow the link. platform systems
power line test systems
Combination & Ring wave test system (PIM 100, PIM 110 ; PCD 100 or PCD 130) Combination waves or Hybrids (U: 1.2/50µs open circuit, I: 8/20µs short circuit, PIM100) , are used in a wide range of test applications. The most common use is to simulate lightning impulses coupled onto the domestic single or three phase supplies. Standards such as IEC 61000-4-5 Ed. 1 & 2 and ANSI C62.41 require this type of impulse.
Ring waves (0.5µs rise-time, 100kHz frequency, PIM110), are used to simulate lightning or switching effects in domestic single or three phase supplies within an adequately protected building. The waveform has similar characteristics in both open and short circuit conditions. The ring wave is characterised as a bipolar damped oscillating wave. Standards such as IEC 61000-4-12 and ANSI C62.41 require this type of waveform.  | Features - Impulse voltage up to 7.4kV
- 3.7kA short circuit current
- Oscilloscope Impulse monitor outputs
- Multiple applications
- Automatic polarity switching
- single and three phase CDNs
- telecommunication couplers
- combination waves for IEC & ANSI
- 2ohm source impedance for combination waveform
- 100 kHz ring wave for IEC and ANSI up to 7.8kV
- Output impedance 12ohm, 30ohm & 200ohm (ring wave)
- Fully automatic AC and DC power line couplers up to 32A per phase (PCD100 or PCD130) with dual/triple inputs.
|
Fulfills Combination and Ring Wave parts of the following standards: IEC 61000-4-5 Ed. 1 & 2, ANSI C62.41/45, IEC 61000-4-12, ITU K 20, ITU K 45 and EN 300 386-2 Benefits Consistent pulse parameters
Totally reproducible test results
Easy verification of impulse
No reconfiguration during testing
"single connect system" | Integrated personnel & test object safety
Fully automated by WinFEAT&R control
and reporting software
A modular expandable system that grows
with your application needs
|
Oscillating wave 100kHz, 1MHz test system (PIM 150) Damped oscillating waves are characteristic of interference generated by switching in power circuits. They are characterized by low energy; very fast rise time bipolar bursts with a high repetition rate. Applications are for the testing of : protective relays, data logging, alarm and control equipment connected to three phase power lines.  | Features - 100kHz & 1MHz frequencies with 75ns rise-time
- 40 & 400Hz repetition rates with variable burst durations
- Impulse voltage up to 3.3kV
- Impedance 200ohm
- Automatic polarity switching
- Three phase 16A CDN, 480Vac and 110Vdc
- Remote control using WinFEAT&R software
|
One solution for: IEC 60255-22-1, IEC 60255-3, IEC 61000-4-12 (partial; full compliant with additional PIM110) IEEE C37.90.1-2002 (partial; full compliant with additional PEFT4010) Benefits Consistent pulse parameters
Totally reproducible test results
Easy verification of impulse
No reconfiguration during testing
"single connect system" | Integrated personnel & test object safety
Fully automated by WinFEAT&R control
and reporting software
modular expandable system that grows
with your application needs |
telecommunications test systems
10/700µs test system (PIM 120, PCD 120) To be used for telecommunication and ITE equipment to perform Resistibility tests, Safety tests and EMC tests requiring the 10/700µs high energy surge impulse. Telecom line pulses are characterized by high energy; fast rise time pulses derived from lightning transients modified by the line impedance. Applications are for the testing of customer premise, switching, transmission and supervisory equipment.  | Features - Impulse voltage up to 7.4kV
- 15 and 40ohms switchable impedance
- Oscilloscope Impulse monitors
- User selectable coupling elements
- 4 wire interface
- Automatic polarity switching
- Automatic IEC mode configuration (1,2,3 or 4 lines)
- Gas arrestor, resistor and capacitor coupling modes
- Direct coupling mode
|
One solution for: ITU K 17, 20, 21 & 45, EN 300 386-2, IEC 60950 (partial), UL 1950 (partial), IEC 61000-4-5 Ed. 1 & 2 (partial; full compliant with additional PIM100) Benefits Consistent pulse parameters
Totally reproducible test results
Easy verification of impulse
No reconfiguration during testing
"single connect system" | Integrated personnel & test object safety
Fully automated by WinFEAT&R control
and reporting software
A modular expandable system that grows
with your application needs |
1.2/50µs Telecoms and ITE test system (PIM 130, PCD K22) PIM 130 is a low energy lightning impulse module ideal for ISDN (Telecom) and ITE (Information Technology Equipment) Safety testing. Surge Platform display switches between peak impulse voltage (for ISDN) and capacitor charging voltage (for ITE). Impulse output is either through a 4 wire coupler (ISDN) or direct (ITE)
 | Features - 1.2/50µs voltage pulse
- Maximum impulse voltage 7.4kV
- 1uF charging capacitor
- Source impedance 13 and 40 ohms
- Charging voltage display (IEC mode)
- Impulse voltage display (ITU mode)
- Integrated voltage monitor
- WinFEAT&R integrated
- Additional ISDN coupling box available (PCD K22)
|
One solution for: IEC 60950-1, UL 1950 (partial; full compliant with additional PIM120, PCD120) & ITU K22 Benefits Consistent pulse parameters
Totally reproducible test results
Easy verification of impulse
Easy verification of charging voltage
| Integrated personnel & test object safety
Fully automated by WinFEAT&R control
and reporting software
A modular expandable system that grows
with your application needs |
US requirementsTIA-968-A (FCC part 68 test system) (PIM 800, 810 ; PCD 800, 100 or 130) TIA-968-A (FCC part 68) relates to the testing of Terminal Equipment connected at both residential and commercial premises. The demarcation point between telephone company network and subscriber network determines if TIA-968-A should be used or if another standard may be more appropriate. It applies equally to voice-band analog, Public Switched Digital Services and ISDN Basic Rate Access or Primary Rate Access systems. Testing is required on both the telecom ports and any power ports. Section 68.302 refers specifically to surge impulse tests. Terminal equipment can be telephones, fax machines, modems, answering machines, etc. Testing is required with equipment in it's normal functioning state. Surges must be applied to the Tip and Ring connections in both metallic and Longitudinal modes.  | Features - TIA-968-A (FCC part 68) hybrid Telecom line surges type A and B
- 10/160µs
- 10/560µs
- 9/720µs
- Power line surges
- 2/10µs
- Integrated automatic single and three phase AC & DC power line couplers
- Integrated 4-wire Tip and Ring coupler
|
One solution for: A complete TIA-968-A (FCC part 68) Surge Test System Benefits Consistent pulse parameters
Totally reproducible test results
Easy verification of impulse
No reconfiguration during testing
"single connect system"
RJ 11, 12, 45 telecom adaptors available. | Integrated personnel & test object safety
Fully automated by WinFEAT&R control
and reporting software
A modular expandable system that grows
with your application needs |
Telcordia GR 1089 (Bellcore) test system (PIM 900, 910, 930, 100 ; PCD 900, 100 or 130) GR-1089-CORE (1999) relates to testing of lightning and AC power fault surges in a telecommunications central office environment. Section 4 deals with the design and calibration of test equipment plus definition of test levels on telecommunication ports such as line cards. Test impulses are applied with the system in an idle condition, that is not transmitting or receiving data. However dc voltages may be present on the tip and ring pairs. Recommended equipment from section 4 of GR-1089-CORE for testing network systems: - 10/360µs, True 3 Terminal
- 10/360µs, 12 pair
- 10/1000µs, True 3 Terminal
- 2/10µs, True 5 Terminal
| - 2 wire Tip and Ring coupler
- 4 wire Tip and Ring coupler
- 1.2/50µs , 8/20µs Hybrid
- AC mains coupler
|
 | Features - Single and three phase mains systems
- Full hybrid waveforms according to the latest GR-1089-Core section 4
- First & second-level lightning surges
- Intra-building lightning surges
- First & second-level lightning surges
- Integrated automatic coupling for 2 and 4 wire telecom systems
- True 3 and 5 terminal surges
- Full 12 Pair solution
- Reliable semiconductor discharge switches
- Flexible test parameter programming
- Automatic test connection switching and coupling component switching.
|
One solution for: Telcordia GR-1089 section 4 (Bellcore), 1st and 2nd Level Lightning Surge: 2, 4 & 24 wire component test systems
UL 1449 impulse test system (PIM 400, PIM 410, PCD 430)
UL 1449 relates to testing of Transient Voltage Surge Suppresors (TVSS). TVSS devices have applications in the home, office and industrial plants. Usually mounted on the load side, their function is to protect electrical equipment from lightning surge effects induced onto power lines. UL 1449 is a batch test performed on production samples connected across the mains power supply.  | Features - Impulse voltages up to 7kV
- 3000A impulse (2 ohm)
- 500A impulse (12 ohm)
- Automatic impulse switching
- 10s impulse repetition rate @ 6kV
- Short circuit fault current on CDN > 200Aac
- Synchronization with each phase
- Reliable semiconductor discharge switch
- Flexible test parameter programming
- Oscilloscope impulse monitors
- 32A 3 phase CDN @ 600V/60Hz
- Impulse shapes defined at CDN output
- Fully remote control using WinFEAT&R software
|
One solution for: UL 1449 AC Power Load Tests (Table 35.1) permanently connected leads UL 1449 requires testing using a range of combination wave impulses superimposed onto AC power supplies. Haefely offer a complete range of instruments to cover these two impulse requirements. | UL 1449 Requirement | Reference | Haefely Equipment | | Measured Limiting Voltage Test | Table 34.1 | PIM 400, PIM 410 & PCD 430 | | AC Power Load Test | Table 35.1 | PIM 400, PCD 430 |
Benefits Consistent pulse parameters
Totally reproducible test results
Easy verification of impulse
No reconfiguration during testing
"single connect system" | Integrated personnel & test object safety
Fully automated by WinFEAT&R control
and reporting software
A modular expandable system that grows
with your application needs |
Current impulse component testing (PIM 200)
The PIM200 impulse module is used for component testing with current impulses up to 12kA. Such tests are typically carried out on overvoltage protection elements such as varistors, gas arrestors and avalanche breakdown diodes, ground fault circuit interrupters and overcurrent trip switches, as well as resistibility tests for telecom equipment.  | Features - 8/20 current impulse from 800A to 12kA
- 10/1000 current impulse from 8A to 110A
- Integrated test cabinet
- Clamping voltage display
- Peak current display
- Fully remote control using WinFEAT&R software
|
One solution for: IEC 61008, 61009, 61051, 61643 ANSI C62.31, C62.33, C62.35 UL 943 ITU K20, K44, K45
Benefits Consistent pulse parameters
Totally reproducible test results
Easy verification of impulse
No reconfiguration during testing
"single connect system" | Safety cabinet guarantees safety
Fully automated by WinFEAT&R control
and reporting software
A modular expandable system that grows
with your application needs |
platform modules| Module | Impulse / Function | Standards | | PSURGE 8000 | System Controller / DC source | - | | PIM 100 | Combination wave 1,2/50µs - 8/20µs 7,4kV / 3,7kA Combination Wave / Hybrid | IEC/EN 61000-4-5 edition 1&2 IEEE/ANSI C62.41 Telcordia GR 1089 (Bellcore), EN 300-386 others | | PIM 110 | Ring Wave 100kHz 7,8kV / 12W 100kHz 7,8kV / 30W 100kHz 7,8kV / 200W Ring Wave | IEC/EN 61000-4-12 IEEE/ANSI C62.41 others | | PIM 120 | Telecom impulse 10/700µs - 7,4kV / 15W 10/700µs - 7,4kV / 40W | IEC/EN 61000-4-5 edition 1&2 ITU K series, ETSI / EN 300 386 IEC 60950, UL 1950 others | | PIM 130 | Voltage impulse 1.2/50µs - 7,4kV / 13W 1.2/50µs - 7,4kV / 40W
| IEC 60950, UL 1950 ITU K22 others | | PIM 150 | Damped oscillating wave 100kHz/75ns - 3,3kV 1MHz/75ns - 3.3kV Oscillating wave including CDN 3 phase 480V (L-L) | IEC/EN 61000-4-12 editon 1 IEC/EN 61000-4-18 edition 1 IEC 60255-22-1 IEC 60255-3 ANSI C37.90.1-2002 | | PIM 155 | Oscillating magnetic field 100kHz & 1MHz 100A/m magnetic field | IEC/EN 61000-4-10 | | PIM 200 | Current impulse module 8/20 current 800A - 12kA 10/1000 current 8A - 110A | IEC 61008, 61009, 61051, 61643 ANSI C62.31, C62.33, C62.35 UL 943 ITU K20, K44, K45 | | PIM 210 | Current impulse module 8/20 current 1A - 1200A 10/1000 current 1A - 11A | IEC 61051, 61643 ANSI C62.33, C62.35 ITU K20, K44, K45 | | PIM 400 | PIM 400 1,2/50µs - 8/20µs 6kV / 3kA Combination Wave / Hybrid | UL 1449 | | PIM 410 | 1,2/50µs - 8/20µs 6kV / 500A Combination Wave / Hybrid | UL 1449 | | PIM 800 | 10/160µs - 1500V / 200A 10/560µs - 800V / 100A 9/720µs - 1500V / 37,5A | TIA-968-A (FCC part 68) | | PIM 810 | 2/10µs - 2500V / 1000A | TIA-968-A (FCC part 68) | | PIM 900 together with PCD 900 only | 2/10µs 2500V / 500A 5 Terminal 2/10µs 5000V / 500A 5 Terminal 2/10µs 1500V / 100A 5 Terminal 2/10µs 800V / 100A 5 Terminal | Telcordia GR 1089 (Bellcore) | | PIM 910 together with PCD 900 only | 10/1000µs - 1000V / 100A 3 Term. 10/1000µs - 600V / 100A 3 Term. 10/360µs - 1000V / 100A 3 Term. | Telcordia GR 1089 (Bellcore) | | PIM 930 | 10/360µs 1000V / 25A 12 Pair system including coupling & decoupling elements | Telcordia GR 1089 (Bellcore) |
platform coupling decoupling modules| Module | Impulse / Function | Standards | | PCD 100 | Combination wave / ring wave CDN 1 phase 16A 264V ac | IEC/EN 61000-4-5 edition 1&2 FCC part 68 Telcordia GR 1089 (Bellcore), ETSI / EN 300 386 others | | PCD 120 | Telecom impulse 4 line CDN for PIM 120 | IEC/EN 61000-4-5 edition 1&2 ITU K series, ETSI / EN 300 386
| | PCD 121 | Coupling network for unshielded symmetrical data and control lines 1.2/50 - 8/20 testing up to 4 wires (2 pairs) signal bandwidth up to some 10MHz | IEC/EN 61000-4-5 | | PCD 122 | Coupling network for unshielded symmetrical data and control lines 10/700 testing up to 4 wires (2 pairs) signal bandwidth up to some 10MHz | IEC/EN 61000-4-5 ITU K44 | | PCD 126A | Coupling network for unshielded symmetrical (ring wave) and assymetrical (CW 1.2/50-8/20us) data and control lines comb. wave 1.2/50 - 8/20 ring wave 100KHz testing up to 4 wires (2 pairs) signal bandwidth up to some MHz | IEC/EN 61000-4-5 IEC/EN 61000-4-12 | | DEC 5 | Decoupling network for unshielded symmetrical data and control lines 1.2/50 - 8/20 10/700 testing up to 4 wires (2 pairs) signal bandwidth up to some 100kHz | IEC/EN 61000-4-5 ITU K44 | | DEC 6 | Decoupling network for unshielded symmetrical data and control lines 1.2/50 - 8/20 10/700 testing up to 4 wires (2 pairs) signal bandwidth up to some 10MHz | ITU K44 FCC part 68 | | DEC 7 | Decoupling network for asymmetrical data and control lines 1.2/50 - 8/20 ring wave 100kHz testing up to 4 wires (2 pairs) signal bandwidth up to some 100Hz | IEC/EN 61000-4-5 IEC/EN 61000-4-12 | | PCD 130 | 3 phase Combination wave / ring wave CDN 3 phase, 32A, 690V (L-L) 3 inputs for "single connect" concept | IEC/EN 61000-4-5 edition 1&2 Ansi C62.41/45 FCC part 68 Telcordia GR 1089 (Bellcore) ETSI/EN 300 386 others | | PCD 150 | Coupling and decoupling network for data and control lines Damped oscillating wave 100kHz and 1MHz Ring wave 100kHz signal bandwidth up to some 10kHz | IEC/EN 61000-4-12 edition 1 IEC/EN 61000-4-18 edition 1 | | PCD 430 | CDN 3 phase 32A 690V (L-L) | UL 1449 | | PCD 800 | 4 Wire Coupling Matrix for PIM 800 | TIA-968-A (FCC Part 68) | | PCD 900 | 4 Wire Matrix for PIM 900 & PIM 910 including coupling & decoupling elements | Telcordia GR 1089 (Bellcore) |
The Surge platform system is constantly growing to meet market needs. Customer specific modules can also be supplied. Please contact us for more information
|